Last revised: February 11, 2014 AquaMetrix 2300 Controller Installation & Operation Manual V1.3 ©Water Analytics 2014 All rights reserved.

Página 2

N116-133 AquaMetrix 2300 Installation and Operation Manual Page 10 1.7. The Web Menu Clicking on one of the five top buttons brings up new screens

Página 3

N116-133 AquaMetrix 2300 Installation and Operation Manual Page 11 2. Installation and Housekeeping Mount the 2300 Controller through the front pa

Página 4

N116-133 AquaMetrix 2300 Installation and Operation Manual Page 12 Apply power on to the 2300 Controller. The front panel will first display a spl

Página 5 - 1. Overview

N116-133 AquaMetrix 2300 Installation and Operation Manual Page 13 3. File delivery is by manual download from browser, and 4. Data is stored for

Página 6 - 1.3. Front Panel Display

N116-133 AquaMetrix 2300 Installation and Operation Manual Page 14 Wiring of a pulse rate sensor is shown below in Figure 7. The three wires from a

Página 7 - AquaMetrix 2300

N116-133 AquaMetrix 2300 Installation and Operation Manual Page 15 Figure 8 - Probe Configuration web page 3.4. The Probe Configuration Wizard Se

Página 8 - 1.6. Probe Status Screen

N116-133 AquaMetrix 2300 Installation and Operation Manual Page 16 The probe definition page is shown in Figure 9 below. There are seven choices o

Página 9

N116-133 AquaMetrix 2300 Installation and Operation Manual Page 17 Figure 10 - Probe Configuration Wizard, page 2 Whether or not the scaling opera

Página 10 - 1.7. The Web Menu

N116-133 AquaMetrix 2300 Installation and Operation Manual Page 18 Figure 11 - Probe Configuration Wizard, page 3 Note that any changes to the sca

Página 11

N116-133 AquaMetrix 2300 Installation and Operation Manual Page 19 isn’t known beforehand. A data point can also be deleted with the appropriate se

Página 12 - 2.4. Configure Data Logging

N116-133 AquaMetrix 2300 Installation and Operation Manual Page 2 For Your Safety Please read this entire manual before unpacking, setting up or

Página 13

N116-133 AquaMetrix 2300 Installation and Operation Manual Page 20 3.7. Scale Factor The Scale Factor option just multiplies the scale factor enter

Página 14

N116-133 AquaMetrix 2300 Installation and Operation Manual Page 21 Monitors for the other probes. The Period Counter Alarm will go off each time a

Página 15

N116-133 AquaMetrix 2300 Installation and Operation Manual Page 22 5. Configuring Alarms, Relays, and Notifications Each probe can be monitored to

Página 16

N116-133 AquaMetrix 2300 Installation and Operation Manual Page 23 2. Instead of green lights for the monitors on both the web probe status screen

Página 17

N116-133 AquaMetrix 2300 Installation and Operation Manual Page 24 Figure 15 - Probe Configuration Wizard, page 6, Relay drop down menu Figure 16

Página 18 - 3.6. Non-Linear Scaling

N116-133 AquaMetrix 2300 Installation and Operation Manual Page 25 calibrated units selected for the probe. For a high alarm or control, the trip p

Página 19

N116-133 AquaMetrix 2300 Installation and Operation Manual Page 26 5.2. Configuring for Email Notification Clicking on Next after selecting Send at

Página 20 - 3.8. K-Factor Scaling

N116-133 AquaMetrix 2300 Installation and Operation Manual Page 27 Table 3 - Email domain names for common hosts. Carrier Email Address Verizon Wi

Página 21

N116-133 AquaMetrix 2300 Installation and Operation Manual Page 28 6.1. Data Logging Configuration Wizard Data logging will send all sensor informa

Página 22 - 5.1. Types of Monitors

N116-133 AquaMetrix 2300 Installation and Operation Manual Page 29 7. User Maintenance and Passwords 7.1. Web Passwords The 2300 Controller is pa

Página 23

N116-133 AquaMetrix 2300 Installation and Operation Manual Page 3 2300 Multi-Parameter Controller Table of Contents AquaMetrix+2300+Controller+Ins

Página 24

N116-133 AquaMetrix 2300 Installation and Operation Manual Page 30 Figure 21 - LCD Configuration Dialogue 8. Operating the 2300 without a Network

Página 25

N116-133 AquaMetrix 2300 Installation and Operation Manual Page 31 Figure 22- Menu pages for the probe in slot 1, Tank pH, showing the first ca

Página 26

N116-133 AquaMetrix 2300 Installation and Operation Manual Page 32 Figure 24 – Calibration screens for probes with K Factor scaling. 8.2. Front Pa

Página 27 - 6. Logs and Data Logging

N116-133 AquaMetrix 2300 Installation and Operation Manual Page 33 Figure 26 – Change screens for relay trip and reset points. 8.3. Front Panel

Página 28 - 6.2. Alarm Logs

N116-133 AquaMetrix 2300 Installation and Operation Manual Page 34 port forwarding, also called port mapping. We recommend talking to your IT depa

Página 29 - 7.1. Web Passwords

N116-133 AquaMetrix 2300 Installation and Operation Manual Page 35 solution. This will allow the wireless connection of the 2300 to a wifi-capable

Página 30

N116-133 AquaMetrix 2300 Installation and Operation Manual Page 36 b. Default Gateway: 192.168.7.7 c. Subnet Mask: 255.255.255.0. Note that the I

Página 31

N116-133 AquaMetrix 2300 Installation and Operation Manual Page 37 10.2. Web Server and TFTP Server Setups The second submenu is the Web Server S

Página 32

N116-133 AquaMetrix 2300 Installation and Operation Manual Page 38 Figure 27 - Email configuration The second submenu is Send Test Email, which ge

Página 33 - 9.1. Dynamic IP Setup

N116-133 AquaMetrix 2300 Installation and Operation Manual Page 39 Monitor Name {{#relayname}} Name of the Monitor (relay or control) that was trig

Página 34

N116-133 AquaMetrix 2300 Installation and Operation Manual Page 4 -#.#! A(%2,I*',%I!2('!?J3,8!Q(&,2,+3&,(%!######################

Página 35

N116-133 AquaMetrix 2300 Installation and Operation Manual Page 40 There is another user-selected option on this menu - Automatically enable all pr

Página 36 - 10. Network Setup

N116-133 AquaMetrix 2300 Installation and Operation Manual Page 41 • TO Address. This is the email address used for sending the above error mes

Página 37 - 10.3. Email Setup

N116-133 AquaMetrix 2300 Installation and Operation Manual Page 42 Table 5 - Advanced set-up parameters Menu Item Function List logged in users Pro

Página 38 - 10.4. Email Keyword List

N116-133 AquaMetrix 2300 Installation and Operation Manual Page 43 13.2. 6-channel Relay Output card The 6-channel Relay Output card provides four

Página 39 - 11. Configuring the System

N116-133 AquaMetrix 2300 Installation and Operation Manual Page 44 Figure 32 – Analog output card connector. 14. Rebuilding a Corrupted Internal

Página 40 - 11.4. Error Handling

N116-133 AquaMetrix 2300 Installation and Operation Manual Page 45 15. Panel Mounting Dimensions 3.65 3.65 MINIMUM INTERIOR CLEARENCE4.80 Max P

Página 41 - 12. Advanced Setup

N116-133 AquaMetrix 2300 Installation and Operation Manual Page 5 1. Overview 1.1. Introduction The AquaMetrix 2300 Controller is a multi-input co

Página 42

N116-133 AquaMetrix 2300 Installation and Operation Manual Page 6 Current 0.3 A Temperature 0 to 70 0C Protection NEMA 4X, 1/4 DIN panel mount or

Página 43

N116-133 AquaMetrix 2300 Installation and Operation Manual Page 7 Pressing the Down arrow will cycle through all of the individual probe screens.

Página 44

N116-133 AquaMetrix 2300 Installation and Operation Manual Page 8 These functions are geared to ensuring that the unit may be connected to a compu

Página 45 - CLEARENCE

N116-133 AquaMetrix 2300 Installation and Operation Manual Page 9 Figure 2 - Probe status screen. The screen lists all enabled sensors. Figure 3